力士乐4WREQ 6 V32-2X/V5C-24PF60 技术参数说明
Material No.
R901338149
Unit system: metric
Open allClose all
Features
Product description
Set-up:
Valve with integrated sensors:
The valve basically consists of:
Housing (1) and pressure sensor plate (12) with connection surface
Control spool (2) with compression springs (3 and 4) and spring plates (8 and 9)
Coils (5 and 6) and pole tubes (14 and 15) with central thread
Position transducer (7)
Integrated pressure sensors (10)
Integrated digital control electronics IAC-P (11)
Functional description
With de-energized solenoids (5 and 6), the control spool (2) is brought into the central position by compression springs (3 and 4) between the spring plates (8 and 9) (with V spool valve without spring plate). With V spool valves, the mechanical zero position does not correspond to the hydraulic one.
Depending on the valve type, the following functions result (some of them can be combined):
Flow control (Q)
Flow control (Q)
Pressure control in A and/or B (p)
Force control (p)
Substitutional control p/Q
The command value presetting can alternatively be specified via an analog interface (X1) or via the field bus interface (X2, X3).
The actual value signals are provided via an analog interface (X1) and can additionally be read out via the field bus (X2, X3).
The controller parameters are set via the field bus
Separate supply voltage for bus/controller and power part (output stage) for safety reasons
The digital integrated control electronics enables the following error detection:
Cable break pressure sensor (10)
Undervoltage
Cable break position transducer (7)
Communication error
Watchdog
Cable break command value inputs (only with current interface)
The following additional functions are available:
Ramp generator
Internal command value profile
Enable function analogdigital
Error output 24 V
PC program WIN-PED 6
To implement the project planning task and to parameterize the IFB-P valves, the user may use the WIN-PED commissioning software.
Parameterization
Diagnosis
Comfortable data management on a PC
System requirements
IBM PC or compatible system
Windows 2000 or Windows XP
RAM (recommendation: 256 MB)
150 MB of available hard disk capacity
Notice
The "WIN-PED 6" PC program is not included in the scope of delivery. It is available for free download!
4WREQ 6 with integrated pressure sensors
Set-up:
Valve for external sensor:
The valve basically consists of:
Housing (1) with connection surface
Control spool (2) with compression springs (3 and 4) and spring plates (8 and 9)
Coils (5 and 6) and pole tubes (14 and 15) with central thread
Position transducer (7)
Integrated digital control electronics IAC-P (11)
Port (X4) for an external pressure sensor (12)
Functional description
With de-energized solenoids (5 and 6), the control spool (2) is brought into the central position by compression springs (3 and 4) between the spring plates (8 and 9) (with V spool valve without spring plate). With V spool valves, the mechanical zero position does not correspond to the hydraulic one.
Functions:
Flow control (Q)
Pressure control (p)
Substitutional control p/Q
The command value presetting can alternatively be specified via an analog interface (X1) or via the field bus interface (X2, X3).
The actual value signals are provided via an analog interface (X1) and can additionally be read out via the field bus (X2, X3).
The controller parameters are set via the field bus
Separate supply voltage for bus/controller and power part (output stage) for safety reasons
The digital integrated control electronics enables the following error detection:
Cable break pressure sensor (depending on sensor interface)
Undervoltage
Cable break position transducer (7)
Communication error
Watchdog
Cable break command value inputs (only with current interface)
The following additional functions are available:
Ramp generator
Internal command value profile
Enable function analog?/?digital
Errr output 24 V
PC program WIN-PED 6
To implement the project planning task and to parameterize the IFB-P valves, the user may use the WIN-PED commissioning software.
Parameterization
Diagnosis
Comfortable data management on a PC
System requirements
IBM PC or compatible system
Windows 2000 or Windows XP
RAM (recommendation: 256 MB)
150 MB of available hard disk capacity
Notice
The "WIN-PED 6" PC program is not included in the scope of delivery. It is available for free download!
版权与免责声明:凡本网注明“来源:全球装备网”的所有作品,均为浙江兴旺宝明通网络有限公司-全球装备网合法拥有版权或有权使用的作品,未经本网授权不得转载、摘编或利用其它方式使用上述作品。已经本网授权使用作品的,应在授权范围内使用,并注明“来源:全球装备网”。违反上述声明者,本网将追究其相关法律责任。 本网转载并注明自其它来源(非全球装备网)的作品,目的在于传递更多信息,并不代表本网赞同其观点或和对其真实性负责,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品第一来源,并自负版权等法律责任。 如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系,否则视为放弃相关权利。